github.com/hbdrawn/golang@v0.0.0-20141214014649-6b835209aba2/doc/asm.html (about) 1 <!--{ 2 "Title": "A Quick Guide to Go's Assembler", 3 "Path": "/doc/asm" 4 }--> 5 6 <h2 id="introduction">A Quick Guide to Go's Assembler</h2> 7 8 <p> 9 This document is a quick outline of the unusual form of assembly language used by the <code>gc</code> 10 suite of Go compilers (<code>6g</code>, <code>8g</code>, etc.). 11 The document is not comprehensive. 12 </p> 13 14 <p> 15 The assembler is based on the input to the Plan 9 assemblers, which is documented in detail 16 <a href="http://plan9.bell-labs.com/sys/doc/asm.html">on the Plan 9 site</a>. 17 If you plan to write assembly language, you should read that document although much of it is Plan 9-specific. 18 This document provides a summary of the syntax and 19 describes the peculiarities that apply when writing assembly code to interact with Go. 20 </p> 21 22 <p> 23 The most important thing to know about Go's assembler is that it is not a direct representation of the underlying machine. 24 Some of the details map precisely to the machine, but some do not. 25 This is because the compiler suite (see 26 <a href="http://plan9.bell-labs.com/sys/doc/compiler.html">this description</a>) 27 needs no assembler pass in the usual pipeline. 28 Instead, the compiler emits a kind of incompletely defined instruction set, in binary form, which the linker 29 then completes. 30 In particular, the linker does instruction selection, so when you see an instruction like <code>MOV</code> 31 what the linker actually generates for that operation might not be a move instruction at all, perhaps a clear or load. 32 Or it might correspond exactly to the machine instruction with that name. 33 In general, machine-specific operations tend to appear as themselves, while more general concepts like 34 memory move and subroutine call and return are more abstract. 35 The details vary with architecture, and we apologize for the imprecision; the situation is not well-defined. 36 </p> 37 38 <p> 39 The assembler program is a way to generate that intermediate, incompletely defined instruction sequence 40 as input for the linker. 41 If you want to see what the instructions look like in assembly for a given architecture, say amd64, there 42 are many examples in the sources of the standard library, in packages such as 43 <a href="/pkg/runtime/"><code>runtime</code></a> and 44 <a href="/pkg/math/big/"><code>math/big</code></a>. 45 You can also examine what the compiler emits as assembly code: 46 </p> 47 48 <pre> 49 $ cat x.go 50 package main 51 52 func main() { 53 println(3) 54 } 55 $ go tool 6g -S x.go # or: go build -gcflags -S x.go 56 57 --- prog list "main" --- 58 0000 (x.go:3) TEXT main+0(SB),$8-0 59 0001 (x.go:3) FUNCDATA $0,gcargs·0+0(SB) 60 0002 (x.go:3) FUNCDATA $1,gclocals·0+0(SB) 61 0003 (x.go:4) MOVQ $3,(SP) 62 0004 (x.go:4) PCDATA $0,$8 63 0005 (x.go:4) CALL ,runtime.printint+0(SB) 64 0006 (x.go:4) PCDATA $0,$-1 65 0007 (x.go:4) PCDATA $0,$0 66 0008 (x.go:4) CALL ,runtime.printnl+0(SB) 67 0009 (x.go:4) PCDATA $0,$-1 68 0010 (x.go:5) RET , 69 ... 70 </pre> 71 72 <p> 73 The <code>FUNCDATA</code> and <code>PCDATA</code> directives contain information 74 for use by the garbage collector; they are introduced by the compiler. 75 </p> 76 77 <!-- Commenting out because the feature is gone but it's popular and may come back. 78 79 <p> 80 To see what gets put in the binary after linking, add the <code>-a</code> flag to the linker: 81 </p> 82 83 <pre> 84 $ go tool 6l -a x.6 # or: go build -ldflags -a x.go 85 codeblk [0x2000,0x1d059) at offset 0x1000 86 002000 main.main | (3) TEXT main.main+0(SB),$8 87 002000 65488b0c25a0080000 | (3) MOVQ 2208(GS),CX 88 002009 483b21 | (3) CMPQ SP,(CX) 89 00200c 7707 | (3) JHI ,2015 90 00200e e83da20100 | (3) CALL ,1c250+runtime.morestack00 91 002013 ebeb | (3) JMP ,2000 92 002015 4883ec08 | (3) SUBQ $8,SP 93 002019 | (3) FUNCDATA $0,main.gcargs·0+0(SB) 94 002019 | (3) FUNCDATA $1,main.gclocals·0+0(SB) 95 002019 48c7042403000000 | (4) MOVQ $3,(SP) 96 002021 | (4) PCDATA $0,$8 97 002021 e8aad20000 | (4) CALL ,f2d0+runtime.printint 98 002026 | (4) PCDATA $0,$-1 99 002026 | (4) PCDATA $0,$0 100 002026 e865d40000 | (4) CALL ,f490+runtime.printnl 101 00202b | (4) PCDATA $0,$-1 102 00202b 4883c408 | (5) ADDQ $8,SP 103 00202f c3 | (5) RET , 104 ... 105 </pre> 106 107 --> 108 109 <h3 id="symbols">Symbols</h3> 110 111 <p> 112 Some symbols, such as <code>PC</code>, <code>R0</code> and <code>SP</code>, are predeclared and refer to registers. 113 There are two other predeclared symbols, <code>SB</code> (static base) and <code>FP</code> (frame pointer). 114 All user-defined symbols other than jump labels are written as offsets to these pseudo-registers. 115 </p> 116 117 <p> 118 The <code>SB</code> pseudo-register can be thought of as the origin of memory, so the symbol <code>foo(SB)</code> 119 is the name <code>foo</code> as an address in memory. 120 This form is used to name global functions and data. 121 Adding <code><></code> to the name, as in <code>foo<>(SB)</code>, makes the name 122 visible only in the current source file, like a top-level <code>static</code> declaration in a C file. 123 </p> 124 125 <p> 126 The <code>FP</code> pseudo-register is a virtual frame pointer 127 used to refer to function arguments. 128 The compilers maintain a virtual frame pointer and refer to the arguments on the stack as offsets from that pseudo-register. 129 Thus <code>0(FP)</code> is the first argument to the function, 130 <code>8(FP)</code> is the second (on a 64-bit machine), and so on. 131 When referring to a function argument this way, it is conventional to place the name 132 at the beginning, as in <code>first_arg+0(FP)</code> and <code>second_arg+8(FP)</code>. 133 Some of the assemblers enforce this convention, rejecting plain <code>0(FP)</code> and <code>8(FP)</code>. 134 For assembly functions with Go prototypes, <code>go</code> <code>vet</code> will check that the argument names 135 and offsets match. 136 On 32-bit systems, the low and high 32 bits of a 64-bit value are distinguished by adding 137 a <code>_lo</code> or <code>_hi</code> suffix to the name, as in <code>arg_lo+0(FP)</code> or <code>arg_hi+4(FP)</code>. 138 If a Go prototype does not name its result, the expected assembly name is <code>ret</code>. 139 </p> 140 141 <p> 142 The <code>SP</code> pseudo-register is a virtual stack pointer 143 used to refer to frame-local variables and the arguments being 144 prepared for function calls. 145 It points to the top of the local stack frame, so references should use negative offsets 146 in the range [−framesize, 0): 147 <code>x-8(SP)</code>, <code>y-4(SP)</code>, and so on. 148 On architectures with a real register named <code>SP</code>, the name prefix distinguishes 149 references to the virtual stack pointer from references to the architectural <code>SP</code> register. 150 That is, <code>x-8(SP)</code> and <code>-8(SP)</code> are different memory locations: 151 the first refers to the virtual stack pointer pseudo-register, while the second refers to the 152 hardware's <code>SP</code> register. 153 </p> 154 155 <p> 156 Instructions, registers, and assembler directives are always in UPPER CASE to remind you 157 that assembly programming is a fraught endeavor. 158 (Exception: the <code>g</code> register renaming on ARM.) 159 </p> 160 161 <p> 162 In Go object files and binaries, the full name of a symbol is the 163 package path followed by a period and the symbol name: 164 <code>fmt.Printf</code> or <code>math/rand.Int</code>. 165 Because the assembler's parser treats period and slash as punctuation, 166 those strings cannot be used directly as identifier names. 167 Instead, the assembler allows the middle dot character U+00B7 168 and the division slash U+2215 in identifiers and rewrites them to 169 plain period and slash. 170 Within an assembler source file, the symbols above are written as 171 <code>fmt·Printf</code> and <code>math∕rand·Int</code>. 172 The assembly listings generated by the compilers when using the <code>-S</code> flag 173 show the period and slash directly instead of the Unicode replacements 174 required by the assemblers. 175 </p> 176 177 <p> 178 Most hand-written assembly files do not include the full package path 179 in symbol names, because the linker inserts the package path of the current 180 object file at the beginning of any name starting with a period: 181 in an assembly source file within the math/rand package implementation, 182 the package's Int function can be referred to as <code>·Int</code>. 183 This convention avoids the need to hard-code a package's import path in its 184 own source code, making it easier to move the code from one location to another. 185 </p> 186 187 <h3 id="directives">Directives</h3> 188 189 <p> 190 The assembler uses various directives to bind text and data to symbol names. 191 For example, here is a simple complete function definition. The <code>TEXT</code> 192 directive declares the symbol <code>runtime·profileloop</code> and the instructions 193 that follow form the body of the function. 194 The last instruction in a <code>TEXT</code> block must be some sort of jump, usually a <code>RET</code> (pseudo-)instruction. 195 (If it's not, the linker will append a jump-to-itself instruction; there is no fallthrough in <code>TEXTs</code>.) 196 After the symbol, the arguments are flags (see below) 197 and the frame size, a constant (but see below): 198 </p> 199 200 <pre> 201 TEXT runtime·profileloop(SB),NOSPLIT,$8 202 MOVQ $runtime·profileloop1(SB), CX 203 MOVQ CX, 0(SP) 204 CALL runtime·externalthreadhandler(SB) 205 RET 206 </pre> 207 208 <p> 209 In the general case, the frame size is followed by an argument size, separated by a minus sign. 210 (It's not a subtraction, just idiosyncratic syntax.) 211 The frame size <code>$24-8</code> states that the function has a 24-byte frame 212 and is called with 8 bytes of argument, which live on the caller's frame. 213 If <code>NOSPLIT</code> is not specified for the <code>TEXT</code>, 214 the argument size must be provided. 215 For assembly functions with Go prototypes, <code>go</code> <code>vet</code> will check that the 216 argument size is correct. 217 </p> 218 219 <p> 220 Note that the symbol name uses a middle dot to separate the components and is specified as an offset from the 221 static base pseudo-register <code>SB</code>. 222 This function would be called from Go source for package <code>runtime</code> using the 223 simple name <code>profileloop</code>. 224 </p> 225 226 <p> 227 Global data symbols are defined by a sequence of initializing 228 <code>DATA</code> directives followed by a <code>GLOBL</code> directive. 229 Each <code>DATA</code> directive initializes a section of the 230 corresponding memory. 231 The memory not explicitly initialized is zeroed. 232 The general form of the <code>DATA</code> directive is 233 234 <pre> 235 DATA symbol+offset(SB)/width, value 236 </pre> 237 238 <p> 239 which initializes the symbol memory at the given offset and width with the given value. 240 The <code>DATA</code> directives for a given symbol must be written with increasing offsets. 241 </p> 242 243 <p> 244 The <code>GLOBL</code> directive declares a symbol to be global. 245 The arguments are optional flags and the size of the data being declared as a global, 246 which will have initial value all zeros unless a <code>DATA</code> directive 247 has initialized it. 248 The <code>GLOBL</code> directive must follow any corresponding <code>DATA</code> directives. 249 </p> 250 251 <p> 252 For example, 253 </p> 254 255 <pre> 256 DATA divtab<>+0x00(SB)/4, $0xf4f8fcff 257 DATA divtab<>+0x04(SB)/4, $0xe6eaedf0 258 ... 259 DATA divtab<>+0x3c(SB)/4, $0x81828384 260 GLOBL divtab<>(SB), RODATA, $64 261 262 GLOBL runtime·tlsoffset(SB), NOPTR, $4 263 </pre> 264 265 <p> 266 declares and initializes <code>divtab<></code>, a read-only 64-byte table of 4-byte integer values, 267 and declares <code>runtime·tlsoffset</code>, a 4-byte, implicitly zeroed variable that 268 contains no pointers. 269 </p> 270 271 <p> 272 There may be one or two arguments to the directives. 273 If there are two, the first is a bit mask of flags, 274 which can be written as numeric expressions, added or or-ed together, 275 or can be set symbolically for easier absorption by a human. 276 Their values, defined in the standard <code>#include</code> file <code>textflag.h</code>, are: 277 </p> 278 279 <ul> 280 <li> 281 <code>NOPROF</code> = 1 282 <br> 283 (For <code>TEXT</code> items.) 284 Don't profile the marked function. This flag is deprecated. 285 </li> 286 <li> 287 <code>DUPOK</code> = 2 288 <br> 289 It is legal to have multiple instances of this symbol in a single binary. 290 The linker will choose one of the duplicates to use. 291 </li> 292 <li> 293 <code>NOSPLIT</code> = 4 294 <br> 295 (For <code>TEXT</code> items.) 296 Don't insert the preamble to check if the stack must be split. 297 The frame for the routine, plus anything it calls, must fit in the 298 spare space at the top of the stack segment. 299 Used to protect routines such as the stack splitting code itself. 300 </li> 301 <li> 302 <code>RODATA</code> = 8 303 <br> 304 (For <code>DATA</code> and <code>GLOBL</code> items.) 305 Put this data in a read-only section. 306 </li> 307 <li> 308 <code>NOPTR</code> = 16 309 <br> 310 (For <code>DATA</code> and <code>GLOBL</code> items.) 311 This data contains no pointers and therefore does not need to be 312 scanned by the garbage collector. 313 </li> 314 <li> 315 <code>WRAPPER</code> = 32 316 <br> 317 (For <code>TEXT</code> items.) 318 This is a wrapper function and should not count as disabling <code>recover</code>. 319 </li> 320 </ul> 321 322 <h3 id="runtime">Runtime Coordination</h3> 323 324 <p> 325 For garbage collection to run correctly, the runtime must know the 326 location of pointers in all global data and in most stack frames. 327 The Go compiler emits this information when compiling Go source files, 328 but assembly programs must define it explicitly. 329 </p> 330 331 <p> 332 A data symbol marked with the <code>NOPTR</code> flag (see above) 333 is treated as containing no pointers to runtime-allocated data. 334 A data symbol with the <code>RODATA</code> flag 335 is allocated in read-only memory and is therefore treated 336 as implicitly marked <code>NOPTR</code>. 337 A data symbol with a total size smaller than a pointer 338 is also treated as implicitly marked <code>NOPTR</code>. 339 It is not possible to define a symbol containing pointers in an assembly source file; 340 such a symbol must be defined in a Go source file instead. 341 Assembly source can still refer to the symbol by name 342 even without <code>DATA</code> and <code>GLOBL</code> directives. 343 A good general rule of thumb is to define all non-<code>RODATA</code> 344 symbols in Go instead of in assembly. 345 </p> 346 347 <p> 348 Each function also needs annotations giving the location of 349 live pointers in its arguments, results, and local stack frame. 350 For an assembly function with no pointer results and 351 either no local stack frame or no function calls, 352 the only requirement is to define a Go prototype for the function 353 in a Go source file in the same package. 354 For more complex situations, explicit annotation is needed. 355 These annotations use pseudo-instructions defined in the standard 356 <code>#include</code> file <code>funcdata.h</code>. 357 </p> 358 359 <p> 360 If a function has no arguments and no results, 361 the pointer information can be omitted. 362 This is indicated by an argument size annotation of <code>$<i>n</i>-0</code> 363 on the <code>TEXT</code> instruction. 364 Otherwise, pointer information must be provided by 365 a Go prototype for the function in a Go source file, 366 even for assembly functions not called directly from Go. 367 (The prototype will also let <code>go</code> <code>vet</code> check the argument references.) 368 At the start of the function, the arguments are assumed 369 to be initialized but the results are assumed uninitialized. 370 If the results will hold live pointers during a call instruction, 371 the function should start by zeroing the results and then 372 executing the pseudo-instruction <code>GO_RESULTS_INITIALIZED</code>. 373 This instruction records that the results are now initialized 374 and should be scanned during stack movement and garbage collection. 375 It is typically easier to arrange that assembly functions do not 376 return pointers or do not contain call instructions; 377 no assembly functions in the standard library use 378 <code>GO_RESULTS_INITIALIZED</code>. 379 </p> 380 381 <p> 382 If a function has no local stack frame, 383 the pointer information can be omitted. 384 This is indicated by a local frame size annotation of <code>$0-<i>n</i></code> 385 on the <code>TEXT</code> instruction. 386 The pointer information can also be omitted if the 387 function contains no call instructions. 388 Otherwise, the local stack frame must not contain pointers, 389 and the assembly must confirm this fact by executing the 390 pseudo-instruction <code>NO_LOCAL_POINTERS</code>. 391 Because stack resizing is implemented by moving the stack, 392 the stack pointer may change during any function call: 393 even pointers to stack data must not be kept in local variables. 394 </p> 395 396 <h2 id="architectures">Architecture-specific details</h2> 397 398 <p> 399 It is impractical to list all the instructions and other details for each machine. 400 To see what instructions are defined for a given machine, say 32-bit Intel x86, 401 look in the top-level header file for the corresponding linker, in this case <code>8l</code>. 402 That is, the file <code>$GOROOT/src/cmd/8l/8.out.h</code> contains a C enumeration, called <code>as</code>, 403 of the instructions and their spellings as known to the assembler and linker for that architecture. 404 In that file you'll find a declaration that begins 405 </p> 406 407 <pre> 408 enum as 409 { 410 AXXX, 411 AAAA, 412 AAAD, 413 AAAM, 414 AAAS, 415 AADCB, 416 ... 417 </pre> 418 419 <p> 420 Each instruction begins with a initial capital <code>A</code> in this list, so <code>AADCB</code> 421 represents the <code>ADCB</code> (add carry byte) instruction. 422 The enumeration is in alphabetical order, plus some late additions (<code>AXXX</code> occupies 423 the zero slot as an invalid instruction). 424 The sequence has nothing to do with the actual encoding of the machine instructions. 425 Again, the linker takes care of that detail. 426 </p> 427 428 <p> 429 One detail evident in the examples from the previous sections is that data in the instructions flows from left to right: 430 <code>MOVQ</code> <code>$0,</code> <code>CX</code> clears <code>CX</code>. 431 This convention applies even on architectures where the usual mode is the opposite direction. 432 </p> 433 434 <p> 435 Here follows some descriptions of key Go-specific details for the supported architectures. 436 </p> 437 438 <h3 id="x86">32-bit Intel 386</h3> 439 440 <p> 441 The runtime pointer to the <code>g</code> structure is maintained 442 through the value of an otherwise unused (as far as Go is concerned) register in the MMU. 443 A OS-dependent macro <code>get_tls</code> is defined for the assembler if the source includes 444 an architecture-dependent header file, like this: 445 </p> 446 447 <pre> 448 #include "zasm_GOOS_GOARCH.h" 449 </pre> 450 451 <p> 452 Within the runtime, the <code>get_tls</code> macro loads its argument register 453 with a pointer to the <code>g</code> pointer, and the <code>g</code> struct 454 contains the <code>m</code> pointer. 455 The sequence to load <code>g</code> and <code>m</code> using <code>CX</code> looks like this: 456 </p> 457 458 <pre> 459 get_tls(CX) 460 MOVL g(CX), AX // Move g into AX. 461 MOVL g_m(AX), BX // Move g->m into BX. 462 </pre> 463 464 <h3 id="amd64">64-bit Intel 386 (a.k.a. amd64)</h3> 465 466 <p> 467 The assembly code to access the <code>m</code> and <code>g</code> 468 pointers is the same as on the 386, except it uses <code>MOVQ</code> rather than 469 <code>MOVL</code>: 470 </p> 471 472 <pre> 473 get_tls(CX) 474 MOVQ g(CX), AX // Move g into AX. 475 MOVQ g_m(AX), BX // Move g->m into BX. 476 </pre> 477 478 <h3 id="arm">ARM</h3> 479 480 <p> 481 The registers <code>R10</code> and <code>R11</code> 482 are reserved by the compiler and linker. 483 </p> 484 485 <p> 486 <code>R10</code> points to the <code>g</code> (goroutine) structure. 487 Within assembler source code, this pointer must be referred to as <code>g</code>; 488 the name <code>R10</code> is not recognized. 489 </p> 490 491 <p> 492 To make it easier for people and compilers to write assembly, the ARM linker 493 allows general addressing forms and pseudo-operations like <code>DIV</code> or <code>MOD</code> 494 that may not be expressible using a single hardware instruction. 495 It implements these forms as multiple instructions, often using the <code>R11</code> register 496 to hold temporary values. 497 Hand-written assembly can use <code>R11</code>, but doing so requires 498 being sure that the linker is not also using it to implement any of the other 499 instructions in the function. 500 </p> 501 502 <p> 503 When defining a <code>TEXT</code>, specifying frame size <code>$-4</code> 504 tells the linker that this is a leaf function that does not need to save <code>LR</code> on entry. 505 </p> 506 507 <p> 508 The name <code>SP</code> always refers to the virtual stack pointer described earlier. 509 For the hardware register, use <code>R13</code>. 510 </p> 511 512 <h3 id="unsupported_opcodes">Unsupported opcodes</h3> 513 514 <p> 515 The assemblers are designed to support the compiler so not all hardware instructions 516 are defined for all architectures: if the compiler doesn't generate it, it might not be there. 517 If you need to use a missing instruction, there are two ways to proceed. 518 One is to update the assembler to support that instruction, which is straightforward 519 but only worthwhile if it's likely the instruction will be used again. 520 Instead, for simple one-off cases, it's possible to use the <code>BYTE</code> 521 and <code>WORD</code> directives 522 to lay down explicit data into the instruction stream within a <code>TEXT</code>. 523 Here's how the 386 runtime defines the 64-bit atomic load function. 524 </p> 525 526 <pre> 527 // uint64 atomicload64(uint64 volatile* addr); 528 // so actually 529 // void atomicload64(uint64 *res, uint64 volatile *addr); 530 TEXT runtime·atomicload64(SB), NOSPLIT, $0-8 531 MOVL ptr+0(FP), AX 532 LEAL ret_lo+4(FP), BX 533 BYTE $0x0f; BYTE $0x6f; BYTE $0x00 // MOVQ (%EAX), %MM0 534 BYTE $0x0f; BYTE $0x7f; BYTE $0x03 // MOVQ %MM0, 0(%EBX) 535 BYTE $0x0F; BYTE $0x77 // EMMS 536 RET 537 </pre>