github.com/netdata/go.d.plugin@v0.58.1/modules/upsd/metadata.yaml (about)

     1  plugin_name: go.d.plugin
     2  modules:
     3    - meta:
     4        id: collector-go.d.plugin-upsd
     5        plugin_name: go.d.plugin
     6        module_name: upsd
     7        monitored_instance:
     8          name: UPS (NUT)
     9          link: ""
    10          icon_filename: plug-circle-bolt.svg
    11          categories:
    12            - data-collection.ups
    13        keywords:
    14          - ups
    15          - nut
    16        related_resources:
    17          integrations:
    18            list: []
    19        info_provided_to_referring_integrations:
    20          description: ""
    21        most_popular: false
    22      overview:
    23        data_collection:
    24          metrics_description: |
    25            This collector monitors Uninterruptible Power Supplies by polling the UPS daemon using the NUT network protocol.
    26          method_description: ""
    27        supported_platforms:
    28          include: []
    29          exclude: []
    30        multi_instance: true
    31        additional_permissions:
    32          description: ""
    33        default_behavior:
    34          auto_detection:
    35            description: ""
    36          limits:
    37            description: ""
    38          performance_impact:
    39            description: ""
    40      setup:
    41        prerequisites:
    42          list: []
    43        configuration:
    44          file:
    45            name: go.d/upsd.conf
    46          options:
    47            description: |
    48              The following options can be defined globally: update_every, autodetection_retry.
    49            folding:
    50              title: Config options
    51              enabled: true
    52            list:
    53              - name: update_every
    54                description: Data collection frequency.
    55                default_value: 1
    56                required: false
    57              - name: autodetection_retry
    58                description: Recheck interval in seconds. Zero means no recheck will be scheduled.
    59                default_value: 0
    60                required: false
    61              - name: address
    62                description: UPS daemon address in IP:PORT format.
    63                default_value: 127.0.0.1:3493
    64                required: true
    65              - name: timeout
    66                description: Connection/read/write timeout in seconds. The timeout includes name resolution, if required.
    67                default_value: 2
    68                required: false
    69          examples:
    70            folding:
    71              title: Config
    72              enabled: true
    73            list:
    74              - name: Basic
    75                description: A basic example configuration.
    76                config: |
    77                  jobs:
    78                    - name: local
    79                      address: 127.0.0.1:3493
    80              - name: Multi-instance
    81                description: |
    82                  > **Note**: When you define multiple jobs, their names must be unique.
    83                  
    84                  Collecting metrics from local and remote instances.
    85                config: |
    86                  jobs:
    87                    - name: local
    88                      address: 127.0.0.1:3493
    89                  
    90                    - name: remote
    91                      address: 203.0.113.0:3493
    92      troubleshooting:
    93        problems:
    94          list: []
    95      alerts:
    96        - name: upsd_10min_ups_load
    97          metric: upsd.ups_load
    98          info: "UPS ${label:ups_name} average load over the last 10 minutes"
    99          link: https://github.com/netdata/netdata/blob/master/src/health/health.d/upsd.conf
   100        - name: upsd_ups_battery_charge
   101          metric: upsd.ups_battery_charge
   102          info: "UPS ${label:ups_name} average battery charge over the last minute"
   103          link: https://github.com/netdata/netdata/blob/master/src/health/health.d/upsd.conf
   104        - name: upsd_ups_last_collected_secs
   105          metric: upsd.ups_load
   106          info: "UPS ${label:ups_name} number of seconds since the last successful data collection"
   107          link: https://github.com/netdata/netdata/blob/master/src/health/health.d/upsd.conf
   108      metrics:
   109        folding:
   110          title: Metrics
   111          enabled: false
   112        description: ""
   113        availability: []
   114        scopes:
   115          - name: ups
   116            description: These metrics refer to the UPS unit.
   117            labels:
   118              - name: ups_name
   119                description: UPS name.
   120              - name: battery_type
   121                description: Battery type (chemistry). "battery.type" variable value.
   122              - name: device_model
   123                description: Device model. "device.mode" variable value.
   124              - name: device_serial
   125                description: Device serial number. "device.serial" variable value.
   126              - name: device_manufacturer
   127                description: Device manufacturer. "device.mfr" variable value.
   128              - name: device_type
   129                description: Device type (ups, pdu, scd, psu, ats). "device.type" variable value.
   130            metrics:
   131              - name: upsd.ups_load
   132                description: UPS load
   133                unit: percentage
   134                chart_type: area
   135                dimensions:
   136                  - name: load
   137              - name: upsd.ups_load_usage
   138                description: UPS load usage (power output)
   139                unit: Watts
   140                chart_type: line
   141                dimensions:
   142                  - name: load_usage
   143              - name: upsd.ups_status
   144                description: UPS status
   145                unit: status
   146                chart_type: line
   147                dimensions:
   148                  - name: on_line
   149                  - name: on_battery
   150                  - name: low_battery
   151                  - name: high_battery
   152                  - name: replace_battery
   153                  - name: charging
   154                  - name: discharging
   155                  - name: bypass
   156                  - name: calibration
   157                  - name: offline
   158                  - name: overloaded
   159                  - name: trim_input_voltage
   160                  - name: boost_input_voltage
   161                  - name: forced_shutdown
   162                  - name: other
   163              - name: upsd.ups_temperature
   164                description: UPS temperature
   165                unit: Celsius
   166                chart_type: line
   167                dimensions:
   168                  - name: temperature
   169              - name: upsd.ups_battery_charge
   170                description: UPS Battery charge
   171                unit: percentage
   172                chart_type: area
   173                dimensions:
   174                  - name: charge
   175              - name: upsd.ups_battery_estimated_runtime
   176                description: UPS Battery estimated runtime
   177                unit: seconds
   178                chart_type: line
   179                dimensions:
   180                  - name: runtime
   181              - name: upsd.ups_battery_voltage
   182                description: UPS Battery voltage
   183                unit: Volts
   184                chart_type: line
   185                dimensions:
   186                  - name: voltage
   187              - name: upsd.ups_battery_voltage_nominal
   188                description: UPS Battery voltage nominal
   189                unit: Volts
   190                chart_type: line
   191                dimensions:
   192                  - name: nominal_voltage
   193              - name: upsd.ups_input_voltage
   194                description: UPS Input voltage
   195                unit: Volts
   196                chart_type: line
   197                dimensions:
   198                  - name: voltage
   199              - name: upsd.ups_input_voltage_nominal
   200                description: UPS Input voltage nominal
   201                unit: Volts
   202                chart_type: line
   203                dimensions:
   204                  - name: nominal_voltage
   205              - name: upsd.ups_input_current
   206                description: UPS Input current
   207                unit: Ampere
   208                chart_type: line
   209                dimensions:
   210                  - name: current
   211              - name: upsd.ups_input_current_nominal
   212                description: UPS Input current nominal
   213                unit: Ampere
   214                chart_type: line
   215                dimensions:
   216                  - name: nominal_current
   217              - name: upsd.ups_input_frequency
   218                description: UPS Input frequency
   219                unit: Hz
   220                chart_type: line
   221                dimensions:
   222                  - name: frequency
   223              - name: upsd.ups_input_frequency_nominal
   224                description: UPS Input frequency nominal
   225                unit: Hz
   226                chart_type: line
   227                dimensions:
   228                  - name: nominal_frequency
   229              - name: upsd.ups_output_voltage
   230                description: UPS Output voltage
   231                unit: Volts
   232                chart_type: line
   233                dimensions:
   234                  - name: voltage
   235              - name: upsd.ups_output_voltage_nominal
   236                description: UPS Output voltage nominal
   237                unit: Volts
   238                chart_type: line
   239                dimensions:
   240                  - name: nominal_voltage
   241              - name: upsd.ups_output_current
   242                description: UPS Output current
   243                unit: Ampere
   244                chart_type: line
   245                dimensions:
   246                  - name: current
   247              - name: upsd.ups_output_current_nominal
   248                description: UPS Output current nominal
   249                unit: Ampere
   250                chart_type: line
   251                dimensions:
   252                  - name: nominal_current
   253              - name: upsd.ups_output_frequency
   254                description: UPS Output frequency
   255                unit: Hz
   256                chart_type: line
   257                dimensions:
   258                  - name: frequency
   259              - name: upsd.ups_output_frequency_nominal
   260                description: UPS Output frequency nominal
   261                unit: Hz
   262                chart_type: line
   263                dimensions: