     1  # dmidecode 3.2
     2  Reading SMBIOS/DMI data from file testdata/GigaByte-X399.bin.
     3  SMBIOS 3.1.1 present.
     4  
     5  Handle 0x0000, DMI type 0, 26 bytes
     6  BIOS Information
     7  	Vendor: American Megatrends Inc.
     8  	Version: F4
     9  	Release Date: 10/04/2018
    10  	Address: 0xF0000
    11  	Runtime Size: 64 kB
    12  	ROM Size: 16 MB
    13  	Characteristics:
    14  		PCI is supported
    15  		BIOS is upgradeable
    16  		BIOS shadowing is allowed
    17  		Boot from CD is supported
    18  		Selectable boot is supported
    19  		BIOS ROM is socketed
    20  		EDD is supported
    21  		5.25"/1.2 MB floppy services are supported (int 13h)
    22  		3.5"/720 kB floppy services are supported (int 13h)
    23  		3.5"/2.88 MB floppy services are supported (int 13h)
    24  		Print screen service is supported (int 5h)
    25  		Serial services are supported (int 14h)
    26  		Printer services are supported (int 17h)
    27  		ACPI is supported
    28  		USB legacy is supported
    29  		BIOS boot specification is supported
    30  		Targeted content distribution is supported
    31  		UEFI is supported
    32  	BIOS Revision: 5.14
    33  
    34  Handle 0x0001, DMI type 1, 27 bytes
    35  System Information
    36  	Manufacturer: Gigabyte Technology Co., Ltd.
    37  	Product Name: X399 AORUS XTREME
    38  	Version: Default string
    39  	Serial Number: Default string
    40  	UUID: 032e02b4-0499-0533-a106-940700080009
    41  	Wake-up Type: Power Switch
    42  	SKU Number: Default string
    43  	Family: Default string
    44  
    45  Handle 0x0002, DMI type 2, 15 bytes
    46  Base Board Information
    47  	Manufacturer: Gigabyte Technology Co., Ltd.
    48  	Product Name: X399 AORUS XTREME-CF
    49  	Version: x.x
    50  	Serial Number: Default string
    51  	Asset Tag: Default string
    52  	Features:
    53  		Board is a hosting board
    54  		Board is removable
    55  		Board is replaceable
    56  	Location In Chassis: Default string
    57  	Chassis Handle: 0x0003
    58  	Type: Motherboard
    59  	Contained Object Handles: 0
    60  
    61  Handle 0x0003, DMI type 3, 22 bytes
    62  Chassis Information
    63  	Manufacturer: Default string
    64  	Type: Desktop
    65  	Lock: Not Present
    66  	Version: Default string
    67  	Serial Number: Default string
    68  	Asset Tag: Default string
    69  	Boot-up State: Safe
    70  	Power Supply State: Safe
    71  	Thermal State: Safe
    72  	Security Status: None
    73  	OEM Information: 0x00000000
    74  	Height: Unspecified
    75  	Number Of Power Cords: 1
    76  	Contained Elements: 0
    77  	SKU Number: Default string
    78  
    79  Handle 0x0004, DMI type 10, 6 bytes
    80  On Board Device Information
    81  	Type: Video
    82  	Status: Enabled
    83  	Description:    To Be Filled By O.E.M.
    84  
    85  Handle 0x0005, DMI type 11, 5 bytes
    86  OEM Strings
    87  	String 1: Default string
    88  
    89  Handle 0x0006, DMI type 12, 5 bytes
    90  System Configuration Options
    91  	Option 1: Default string
    92  
    93  Handle 0x0007, DMI type 32, 20 bytes
    94  System Boot Information
    95  	Status: No errors detected
    96  
    97  Handle 0x0008, DMI type 18, 23 bytes
    98  32-bit Memory Error Information
    99  	Type: OK
   100  	Granularity: Unknown
   101  	Operation: Unknown
   102  	Vendor Syndrome: Unknown
   103  	Memory Array Address: Unknown
   104  	Device Address: Unknown
   105  	Resolution: Unknown
   106  
   107  Handle 0x0009, DMI type 16, 23 bytes
   108  Physical Memory Array
   109  	Location: System Board Or Motherboard
   110  	Use: System Memory
   111  	Error Correction Type: None
   112  	Maximum Capacity: 512 GB
   113  	Error Information Handle: 0x0008
   114  	Number Of Devices: 8
   115  
   116  Handle 0x000A, DMI type 19, 31 bytes
   117  Memory Array Mapped Address
   118  	Starting Address: 0x00000000000
   119  	Ending Address: 0x0007FFFFFFF
   120  	Range Size: 2 GB
   121  	Physical Array Handle: 0x0009
   122  	Partition Width: 8
   123  
   124  Handle 0x000B, DMI type 19, 31 bytes
   125  Memory Array Mapped Address
   126  	Starting Address: 0x00100000000
   127  	Ending Address: 0x0207FFFFFFF
   128  	Range Size: 126 GB
   129  	Physical Array Handle: 0x0009
   130  	Partition Width: 8
   131  
   132  Handle 0x000C, DMI type 7, 19 bytes
   133  Cache Information
   134  	Socket Designation: L1 - Cache
   135  	Configuration: Enabled, Not Socketed, Level 1
   136  	Operational Mode: Write Back
   137  	Location: Internal
   138  	Installed Size: 3 MB
   139  	Maximum Size: 3 MB
   140  	Supported SRAM Types:
   141  		Pipeline Burst
   142  	Installed SRAM Type: Pipeline Burst
   143  	Speed: 1 ns
   144  	Error Correction Type: Multi-bit ECC
   145  	System Type: Unified
   146  	Associativity: 8-way Set-associative
   147  
   148  Handle 0x000D, DMI type 7, 19 bytes
   149  Cache Information
   150  	Socket Designation: L2 - Cache
   151  	Configuration: Enabled, Not Socketed, Level 2
   152  	Operational Mode: Write Back
   153  	Location: Internal
   154  	Installed Size: 16 MB
   155  	Maximum Size: 16 MB
   156  	Supported SRAM Types:
   157  		Pipeline Burst
   158  	Installed SRAM Type: Pipeline Burst
   159  	Speed: 1 ns
   160  	Error Correction Type: Multi-bit ECC
   161  	System Type: Unified
   162  	Associativity: 8-way Set-associative
   163  
   164  Handle 0x000E, DMI type 7, 19 bytes
   165  Cache Information
   166  	Socket Designation: L3 - Cache
   167  	Configuration: Enabled, Not Socketed, Level 3
   168  	Operational Mode: Write Back
   169  	Location: Internal
   170  	Installed Size: 64 MB
   171  	Maximum Size: 64 MB
   172  	Supported SRAM Types:
   173  		Pipeline Burst
   174  	Installed SRAM Type: Pipeline Burst
   175  	Speed: 1 ns
   176  	Error Correction Type: Multi-bit ECC
   177  	System Type: Unified
   178  	Associativity: 64-way Set-associative
   179  
   180  Handle 0x000F, DMI type 4, 48 bytes
   181  Processor Information
   182  	Socket Designation: SP3r2
   183  	Type: Central Processor
   184  	Family: Zen
   185  	Manufacturer: Advanced Micro Devices, Inc.
   186  	ID: 82 0F 80 00 FF FB 8B 17
   187  	Signature: Family 23, Model 8, Stepping 2
   188  	Flags:
   189  		FPU (Floating-point unit on-chip)
   190  		VME (Virtual mode extension)
   191  		DE (Debugging extension)
   192  		PSE (Page size extension)
   193  		TSC (Time stamp counter)
   194  		MSR (Model specific registers)
   195  		PAE (Physical address extension)
   196  		MCE (Machine check exception)
   197  		CX8 (CMPXCHG8 instruction supported)
   198  		APIC (On-chip APIC hardware supported)
   199  		SEP (Fast system call)
   200  		MTRR (Memory type range registers)
   201  		PGE (Page global enable)
   202  		MCA (Machine check architecture)
   203  		CMOV (Conditional move instruction supported)
   204  		PAT (Page attribute table)
   205  		PSE-36 (36-bit page size extension)
   206  		CLFSH (CLFLUSH instruction supported)
   207  		MMX (MMX technology supported)
   208  		FXSR (FXSAVE and FXSTOR instructions supported)
   209  		SSE (Streaming SIMD extensions)
   210  		SSE2 (Streaming SIMD extensions 2)
   211  		HTT (Multi-threading)
   212  	Version: AMD Ryzen Threadripper 2990WX 32-Core Processor
   213  	Voltage: 1.0 V
   214  	External Clock: 100 MHz
   215  	Max Speed: 4200 MHz
   216  	Current Speed: 3000 MHz
   217  	Status: Populated, Enabled
   218  	Upgrade: Socket SP3r2
   219  	L1 Cache Handle: 0x000C
   220  	L2 Cache Handle: 0x000D
   221  	L3 Cache Handle: 0x000E
   222  	Serial Number: Unknown
   223  	Asset Tag: Unknown
   224  	Part Number: Unknown
   225  	Core Count: 32
   226  	Core Enabled: 32
   227  	Thread Count: 64
   228  	Characteristics:
   229  		64-bit capable
   230  		Multi-Core
   231  		Hardware Thread
   232  		Execute Protection
   233  		Enhanced Virtualization
   234  		Power/Performance Control
   235  
   236  Handle 0x0010, DMI type 18, 23 bytes
   237  32-bit Memory Error Information
   238  	Type: OK
   239  	Granularity: Unknown
   240  	Operation: Unknown
   241  	Vendor Syndrome: Unknown
   242  	Memory Array Address: Unknown
   243  	Device Address: Unknown
   244  	Resolution: Unknown
   245  
   246  Handle 0x0011, DMI type 17, 40 bytes
   247  Memory Device
   248  	Array Handle: 0x0009
   249  	Error Information Handle: 0x0010
   250  	Total Width: 64 bits
   251  	Data Width: 64 bits
   252  	Size: 16 GB
   253  	Form Factor: DIMM
   254  	Set: None
   255  	Locator: DIMM 0
   256  	Bank Locator: P0 CHANNEL A
   257  	Type: DDR4
   258  	Type Detail: Synchronous Unbuffered (Unregistered)
   259  	Speed: 2933 MT/s
   260  	Manufacturer: Kingston
   261  	Serial Number: 501C661C
   262  	Asset Tag: Not Specified
   263  	Part Number: KHX2933C17D4/16G    
   264  	Rank: 2
   265  	Configured Memory Speed: 2933 MT/s
   266  	Minimum Voltage: 1.2 V
   267  	Maximum Voltage: 1.2 V
   268  	Configured Voltage: 1.2 V
   269  
   270  Handle 0x0012, DMI type 20, 35 bytes
   271  Memory Device Mapped Address
   272  	Starting Address: 0x00000000000
   273  	Ending Address: 0x00FFFFFFFFF
   274  	Range Size: 64 GB
   275  	Physical Device Handle: 0x0011
   276  	Memory Array Mapped Address Handle: 0x000B
   277  	Partition Row Position: Unknown
   278  	Interleave Position: Unknown
   279  	Interleaved Data Depth: Unknown
   280  
   281  Handle 0x0013, DMI type 18, 23 bytes
   282  32-bit Memory Error Information
   283  	Type: OK
   284  	Granularity: Unknown
   285  	Operation: Unknown
   286  	Vendor Syndrome: Unknown
   287  	Memory Array Address: Unknown
   288  	Device Address: Unknown
   289  	Resolution: Unknown
   290  
   291  Handle 0x0014, DMI type 17, 40 bytes
   292  Memory Device
   293  	Array Handle: 0x0009
   294  	Error Information Handle: 0x0013
   295  	Total Width: 64 bits
   296  	Data Width: 64 bits
   297  	Size: 16 GB
   298  	Form Factor: DIMM
   299  	Set: None
   300  	Locator: DIMM 1
   301  	Bank Locator: P0 CHANNEL A
   302  	Type: DDR4
   303  	Type Detail: Synchronous Unbuffered (Unregistered)
   304  	Speed: 2933 MT/s
   305  	Manufacturer: Kingston
   306  	Serial Number: 4E396332
   307  	Asset Tag: Not Specified
   308  	Part Number: KHX2933C17D4/16G    
   309  	Rank: 2
   310  	Configured Memory Speed: 2933 MT/s
   311  	Minimum Voltage: 1.2 V
   312  	Maximum Voltage: 1.2 V
   313  	Configured Voltage: 1.2 V
   314  
   315  Handle 0x0015, DMI type 20, 35 bytes
   316  Memory Device Mapped Address
   317  	Starting Address: 0x00000000000
   318  	Ending Address: 0x00FFFFFFFFF
   319  	Range Size: 64 GB
   320  	Physical Device Handle: 0x0014
   321  	Memory Array Mapped Address Handle: 0x000B
   322  	Partition Row Position: Unknown
   323  	Interleave Position: Unknown
   324  	Interleaved Data Depth: Unknown
   325  
   326  Handle 0x0016, DMI type 18, 23 bytes
   327  32-bit Memory Error Information
   328  	Type: OK
   329  	Granularity: Unknown
   330  	Operation: Unknown
   331  	Vendor Syndrome: Unknown
   332  	Memory Array Address: Unknown
   333  	Device Address: Unknown
   334  	Resolution: Unknown
   335  
   336  Handle 0x0017, DMI type 17, 40 bytes
   337  Memory Device
   338  	Array Handle: 0x0009
   339  	Error Information Handle: 0x0016
   340  	Total Width: 64 bits
   341  	Data Width: 64 bits
   342  	Size: 16 GB
   343  	Form Factor: DIMM
   344  	Set: None
   345  	Locator: DIMM 0
   346  	Bank Locator: P0 CHANNEL B
   347  	Type: DDR4
   348  	Type Detail: Synchronous Unbuffered (Unregistered)
   349  	Speed: 2933 MT/s
   350  	Manufacturer: Kingston
   351  	Serial Number: 533CF631
   352  	Asset Tag: Not Specified
   353  	Part Number: KHX2933C17D4/16G    
   354  	Rank: 2
   355  	Configured Memory Speed: 2933 MT/s
   356  	Minimum Voltage: 1.2 V
   357  	Maximum Voltage: 1.2 V
   358  	Configured Voltage: 1.2 V
   359  
   360  Handle 0x0018, DMI type 20, 35 bytes
   361  Memory Device Mapped Address
   362  	Starting Address: 0x00000000000
   363  	Ending Address: 0x00FFFFFFFFF
   364  	Range Size: 64 GB
   365  	Physical Device Handle: 0x0017
   366  	Memory Array Mapped Address Handle: 0x000B
   367  	Partition Row Position: Unknown
   368  	Interleave Position: Unknown
   369  	Interleaved Data Depth: Unknown
   370  
   371  Handle 0x0019, DMI type 18, 23 bytes
   372  32-bit Memory Error Information
   373  	Type: OK
   374  	Granularity: Unknown
   375  	Operation: Unknown
   376  	Vendor Syndrome: Unknown
   377  	Memory Array Address: Unknown
   378  	Device Address: Unknown
   379  	Resolution: Unknown
   380  
   381  Handle 0x001A, DMI type 17, 40 bytes
   382  Memory Device
   383  	Array Handle: 0x0009
   384  	Error Information Handle: 0x0019
   385  	Total Width: 64 bits
   386  	Data Width: 64 bits
   387  	Size: 16 GB
   388  	Form Factor: DIMM
   389  	Set: None
   390  	Locator: DIMM 1
   391  	Bank Locator: P0 CHANNEL B
   392  	Type: DDR4
   393  	Type Detail: Synchronous Unbuffered (Unregistered)
   394  	Speed: 2933 MT/s
   395  	Manufacturer: Kingston
   396  	Serial Number: 501C6D1C
   397  	Asset Tag: Not Specified
   398  	Part Number: KHX2933C17D4/16G    
   399  	Rank: 2
   400  	Configured Memory Speed: 2933 MT/s
   401  	Minimum Voltage: 1.2 V
   402  	Maximum Voltage: 1.2 V
   403  	Configured Voltage: 1.2 V
   404  
   405  Handle 0x001B, DMI type 20, 35 bytes
   406  Memory Device Mapped Address
   407  	Starting Address: 0x00000000000
   408  	Ending Address: 0x00FFFFFFFFF
   409  	Range Size: 64 GB
   410  	Physical Device Handle: 0x001A
   411  	Memory Array Mapped Address Handle: 0x000B
   412  	Partition Row Position: Unknown
   413  	Interleave Position: Unknown
   414  	Interleaved Data Depth: Unknown
   415  
   416  Handle 0x001C, DMI type 18, 23 bytes
   417  32-bit Memory Error Information
   418  	Type: OK
   419  	Granularity: Unknown
   420  	Operation: Unknown
   421  	Vendor Syndrome: Unknown
   422  	Memory Array Address: Unknown
   423  	Device Address: Unknown
   424  	Resolution: Unknown
   425  
   426  Handle 0x001D, DMI type 17, 40 bytes
   427  Memory Device
   428  	Array Handle: 0x0009
   429  	Error Information Handle: 0x001C
   430  	Total Width: 64 bits
   431  	Data Width: 64 bits
   432  	Size: 16 GB
   433  	Form Factor: DIMM
   434  	Set: None
   435  	Locator: DIMM 0
   436  	Bank Locator: P0 CHANNEL C
   437  	Type: DDR4
   438  	Type Detail: Synchronous Unbuffered (Unregistered)
   439  	Speed: 2933 MT/s
   440  	Manufacturer: Kingston
   441  	Serial Number: 4E1CD81C
   442  	Asset Tag: Not Specified
   443  	Part Number: KHX2933C17D4/16G    
   444  	Rank: 2
   445  	Configured Memory Speed: 2933 MT/s
   446  	Minimum Voltage: 1.2 V
   447  	Maximum Voltage: 1.2 V
   448  	Configured Voltage: 1.2 V
   449  
   450  Handle 0x001E, DMI type 20, 35 bytes
   451  Memory Device Mapped Address
   452  	Starting Address: 0x01000000000
   453  	Ending Address: 0x01FFFFFFFFF
   454  	Range Size: 64 GB
   455  	Physical Device Handle: 0x001D
   456  	Memory Array Mapped Address Handle: 0x000B
   457  	Partition Row Position: Unknown
   458  	Interleave Position: Unknown
   459  	Interleaved Data Depth: Unknown
   460  
   461  Handle 0x001F, DMI type 18, 23 bytes
   462  32-bit Memory Error Information
   463  	Type: OK
   464  	Granularity: Unknown
   465  	Operation: Unknown
   466  	Vendor Syndrome: Unknown
   467  	Memory Array Address: Unknown
   468  	Device Address: Unknown
   469  	Resolution: Unknown
   470  
   471  Handle 0x0020, DMI type 17, 40 bytes
   472  Memory Device
   473  	Array Handle: 0x0009
   474  	Error Information Handle: 0x001F
   475  	Total Width: 64 bits
   476  	Data Width: 64 bits
   477  	Size: 16 GB
   478  	Form Factor: DIMM
   479  	Set: None
   480  	Locator: DIMM 1
   481  	Bank Locator: P0 CHANNEL C
   482  	Type: DDR4
   483  	Type Detail: Synchronous Unbuffered (Unregistered)
   484  	Speed: 2933 MT/s
   485  	Manufacturer: Kingston
   486  	Serial Number: 50395532
   487  	Asset Tag: Not Specified
   488  	Part Number: KHX2933C17D4/16G    
   489  	Rank: 2
   490  	Configured Memory Speed: 2933 MT/s
   491  	Minimum Voltage: 1.2 V
   492  	Maximum Voltage: 1.2 V
   493  	Configured Voltage: 1.2 V
   494  
   495  Handle 0x0021, DMI type 20, 35 bytes
   496  Memory Device Mapped Address
   497  	Starting Address: 0x01000000000
   498  	Ending Address: 0x01FFFFFFFFF
   499  	Range Size: 64 GB
   500  	Physical Device Handle: 0x0020
   501  	Memory Array Mapped Address Handle: 0x000B
   502  	Partition Row Position: Unknown
   503  	Interleave Position: Unknown
   504  	Interleaved Data Depth: Unknown
   505  
   506  Handle 0x0022, DMI type 18, 23 bytes
   507  32-bit Memory Error Information
   508  	Type: OK
   509  	Granularity: Unknown
   510  	Operation: Unknown
   511  	Vendor Syndrome: Unknown
   512  	Memory Array Address: Unknown
   513  	Device Address: Unknown
   514  	Resolution: Unknown
   515  
   516  Handle 0x0023, DMI type 17, 40 bytes
   517  Memory Device
   518  	Array Handle: 0x0009
   519  	Error Information Handle: 0x0022
   520  	Total Width: 64 bits
   521  	Data Width: 64 bits
   522  	Size: 16 GB
   523  	Form Factor: DIMM
   524  	Set: None
   525  	Locator: DIMM 0
   526  	Bank Locator: P0 CHANNEL D
   527  	Type: DDR4
   528  	Type Detail: Synchronous Unbuffered (Unregistered)
   529  	Speed: 2933 MT/s
   530  	Manufacturer: Kingston
   531  	Serial Number: 4F1CE71C
   532  	Asset Tag: Not Specified
   533  	Part Number: KHX2933C17D4/16G    
   534  	Rank: 2
   535  	Configured Memory Speed: 2933 MT/s
   536  	Minimum Voltage: 1.2 V
   537  	Maximum Voltage: 1.2 V
   538  	Configured Voltage: 1.2 V
   539  
   540  Handle 0x0024, DMI type 20, 35 bytes
   541  Memory Device Mapped Address
   542  	Starting Address: 0x01000000000
   543  	Ending Address: 0x01FFFFFFFFF
   544  	Range Size: 64 GB
   545  	Physical Device Handle: 0x0023
   546  	Memory Array Mapped Address Handle: 0x000B
   547  	Partition Row Position: Unknown
   548  	Interleave Position: Unknown
   549  	Interleaved Data Depth: Unknown
   550  
   551  Handle 0x0025, DMI type 18, 23 bytes
   552  32-bit Memory Error Information
   553  	Type: OK
   554  	Granularity: Unknown
   555  	Operation: Unknown
   556  	Vendor Syndrome: Unknown
   557  	Memory Array Address: Unknown
   558  	Device Address: Unknown
   559  	Resolution: Unknown
   560  
   561  Handle 0x0026, DMI type 17, 40 bytes
   562  Memory Device
   563  	Array Handle: 0x0009
   564  	Error Information Handle: 0x0025
   565  	Total Width: 64 bits
   566  	Data Width: 64 bits
   567  	Size: 16 GB
   568  	Form Factor: DIMM
   569  	Set: None
   570  	Locator: DIMM 1
   571  	Bank Locator: P0 CHANNEL D
   572  	Type: DDR4
   573  	Type Detail: Synchronous Unbuffered (Unregistered)
   574  	Speed: 2933 MT/s
   575  	Manufacturer: Kingston
   576  	Serial Number: 543CF131
   577  	Asset Tag: Not Specified
   578  	Part Number: KHX2933C17D4/16G    
   579  	Rank: 2
   580  	Configured Memory Speed: 2933 MT/s
   581  	Minimum Voltage: 1.2 V
   582  	Maximum Voltage: 1.2 V
   583  	Configured Voltage: 1.2 V
   584  
   585  Handle 0x0027, DMI type 20, 35 bytes
   586  Memory Device Mapped Address
   587  	Starting Address: 0x01000000000
   588  	Ending Address: 0x01FFFFFFFFF
   589  	Range Size: 64 GB
   590  	Physical Device Handle: 0x0026
   591  	Memory Array Mapped Address Handle: 0x000B
   592  	Partition Row Position: Unknown
   593  	Interleave Position: Unknown
   594  	Interleaved Data Depth: Unknown
   595  
   596  Handle 0x0028, DMI type 13, 22 bytes
   597  BIOS Language Information
   598  	Language Description Format: Long
   599  	Installable Languages: 15
   600  		en|US|iso8859-1
   601  		zh|TW|unicode
   602  		zh|CN|unicode
   603  		ru|RU|iso8859-5
   604  		de|DE|iso8859-1
   605  		ja|JP|unicode
   606  		ko|KR|unicode
   607  		es|ES|iso8859-1
   608  		fr|FR|iso8859-1
   609  		it|IT|iso8859-1
   610  		pt|PT|iso8859-1
   611  		<BAD INDEX>
   612  		<BAD INDEX>
   613  		<BAD INDEX>
   614  		<BAD INDEX>
   615  	Currently Installed Language: en|US|iso8859-1
   616  
   617  Handle 0x0029, DMI type 8, 9 bytes
   618  Port Connector Information
   619  	Internal Reference Designator: J1602
   620  	Internal Connector Type: None
   621  	External Reference Designator: USB3.1 G1 TypeC
   622  	External Connector Type: Access Bus (USB)
   623  	Port Type: USB
   624  
   625  Handle 0x002A, DMI type 8, 9 bytes
   626  Port Connector Information
   627  	Internal Reference Designator: J1601
   628  	Internal Connector Type: None
   629  	External Reference Designator: USB3.1 G2 TypeC
   630  	External Connector Type: Access Bus (USB)
   631  	Port Type: USB
   632  
   633  Handle 0x002B, DMI type 8, 9 bytes
   634  Port Connector Information
   635  	Internal Reference Designator: J1600
   636  	Internal Connector Type: None
   637  	External Reference Designator: USB3.1 G2 TypeA
   638  	External Connector Type: Access Bus (USB)
   639  	Port Type: USB
   640  
   641  Handle 0x002C, DMI type 8, 9 bytes
   642  Port Connector Information
   643  	Internal Reference Designator: J1300
   644  	Internal Connector Type: None
   645  	External Reference Designator: USB3.1 G1
   646  	External Connector Type: Access Bus (USB)
   647  	Port Type: USB
   648  
   649  Handle 0x002D, DMI type 8, 9 bytes
   650  Port Connector Information
   651  	Internal Reference Designator: J1300
   652  	Internal Connector Type: None
   653  	External Reference Designator: PT RJ45
   654  	External Connector Type: RJ-45
   655  	Port Type: Network Port
   656  
   657  Handle 0x002E, DMI type 8, 9 bytes
   658  Port Connector Information
   659  	Internal Reference Designator: J2000
   660  	Internal Connector Type: None
   661  	External Reference Designator: USB3.1 G1
   662  	External Connector Type: Access Bus (USB)
   663  	Port Type: USB
   664  
   665  Handle 0x002F, DMI type 8, 9 bytes
   666  Port Connector Information
   667  	Internal Reference Designator: J2000
   668  	Internal Connector Type: None
   669  	External Reference Designator: PT RJ45
   670  	External Connector Type: RJ-45
   671  	Port Type: Network Port
   672  
   673  Handle 0x0030, DMI type 8, 9 bytes
   674  Port Connector Information
   675  	Internal Reference Designator: J1503
   676  	Internal Connector Type: None
   677  	External Reference Designator: USB3.1 G1
   678  	External Connector Type: Access Bus (USB)
   679  	Port Type: USB
   680  
   681  Handle 0x0031, DMI type 8, 9 bytes
   682  Port Connector Information
   683  	Internal Reference Designator: J1502
   684  	Internal Connector Type: None
   685  	External Reference Designator: USB3.1 G1
   686  	External Connector Type: Access Bus (USB)
   687  	Port Type: USB
   688  
   689  Handle 0x0032, DMI type 8, 9 bytes
   690  Port Connector Information
   691  	Internal Reference Designator: J2100
   692  	Internal Connector Type: None
   693  	External Reference Designator: Audio Jack
   694  	External Connector Type: Mini Jack (headphones)
   695  	Port Type: Audio Port
   696  
   697  Handle 0x0033, DMI type 8, 9 bytes
   698  Port Connector Information
   699  	Internal Reference Designator: J4306 - MEM FAN
   700  	Internal Connector Type: Other
   701  	External Reference Designator: Not Specified
   702  	External Connector Type: None
   703  	Port Type: Other
   704  
   705  Handle 0x0034, DMI type 8, 9 bytes
   706  Port Connector Information
   707  	Internal Reference Designator: J3000 - ATX PWR
   708  	Internal Connector Type: Other
   709  	External Reference Designator: Not Specified
   710  	External Connector Type: None
   711  	Port Type: Other
   712  
   713  Handle 0x0035, DMI type 8, 9 bytes
   714  Port Connector Information
   715  	Internal Reference Designator: J4300 - SYSTEM FAN
   716  	Internal Connector Type: Other
   717  	External Reference Designator: Not Specified
   718  	External Connector Type: None
   719  	Port Type: Other
   720  
   721  Handle 0x0036, DMI type 8, 9 bytes
   722  Port Connector Information
   723  	Internal Reference Designator: J4305 - CPU FAN
   724  	Internal Connector Type: Other
   725  	External Reference Designator: Not Specified
   726  	External Connector Type: None
   727  	Port Type: Other
   728  
   729  Handle 0x0037, DMI type 8, 9 bytes
   730  Port Connector Information
   731  	Internal Reference Designator: J3001 - ATX 12V PWR
   732  	Internal Connector Type: Other
   733  	External Reference Designator: Not Specified
   734  	External Connector Type: None
   735  	Port Type: Other
   736  
   737  Handle 0x0038, DMI type 8, 9 bytes
   738  Port Connector Information
   739  	Internal Reference Designator: J4301 - MEM FAN
   740  	Internal Connector Type: Other
   741  	External Reference Designator: Not Specified
   742  	External Connector Type: None
   743  	Port Type: Other
   744  
   745  Handle 0x0039, DMI type 8, 9 bytes
   746  Port Connector Information
   747  	Internal Reference Designator: J3002 - ATX 24PIN PWR
   748  	Internal Connector Type: Other
   749  	External Reference Designator: Not Specified
   750  	External Connector Type: None
   751  	Port Type: Other
   752  
   753  Handle 0x003A, DMI type 8, 9 bytes
   754  Port Connector Information
   755  	Internal Reference Designator: J49 - SATA
   756  	Internal Connector Type: Other
   757  	External Reference Designator: Not Specified
   758  	External Connector Type: None
   759  	Port Type: SATA
   760  
   761  Handle 0x003B, DMI type 8, 9 bytes
   762  Port Connector Information
   763  	Internal Reference Designator: J46 - iSATA
   764  	Internal Connector Type: Other
   765  	External Reference Designator: Not Specified
   766  	External Connector Type: None
   767  	Port Type: SATA
   768  
   769  Handle 0x003C, DMI type 8, 9 bytes
   770  Port Connector Information
   771  	Internal Reference Designator: J38 - iSATA
   772  	Internal Connector Type: Other
   773  	External Reference Designator: Not Specified
   774  	External Connector Type: None
   775  	Port Type: SATA
   776  
   777  Handle 0x003D, DMI type 8, 9 bytes
   778  Port Connector Information
   779  	Internal Reference Designator: J43 - iSATA
   780  	Internal Connector Type: Other
   781  	External Reference Designator: Not Specified
   782  	External Connector Type: None
   783  	Port Type: SATA
   784  
   785  Handle 0x003E, DMI type 8, 9 bytes
   786  Port Connector Information
   787  	Internal Reference Designator: J604 - Sink FAN
   788  	Internal Connector Type: Other
   789  	External Reference Designator: Not Specified
   790  	External Connector Type: None
   791  	Port Type: Other
   792  
   793  Handle 0x003F, DMI type 8, 9 bytes
   794  Port Connector Information
   795  	Internal Reference Designator: J4304 - PT FAN
   796  	Internal Connector Type: Other
   797  	External Reference Designator: Not Specified
   798  	External Connector Type: None
   799  	Port Type: Other
   800  
   801  Handle 0x0040, DMI type 8, 9 bytes
   802  Port Connector Information
   803  	Internal Reference Designator: J202 - LPC HDR
   804  	Internal Connector Type: Other
   805  	External Reference Designator: Not Specified
   806  	External Connector Type: None
   807  	Port Type: Other
   808  
   809  Handle 0x0041, DMI type 9, 17 bytes
   810  System Slot Information
   811  	Designation: U1
   812  	Type: x4 M.2 Socket 1-DP
   813  	Current Usage: Available
   814  	Length: Short
   815  	Characteristics:
   816  		3.3 V is provided
   817  		Opening is shared
   818  		PME signal is supported
   819  	Bus Address: 0000:00:01.2
   820  
   821  Handle 0x0042, DMI type 9, 17 bytes
   822  System Slot Information
   823  	Designation: PCIE1
   824  	Type: x8 PCI Express x8
   825  	Current Usage: Available
   826  	Length: Short
   827  	ID: 1
   828  	Characteristics:
   829  		3.3 V is provided
   830  		Opening is shared
   831  		PME signal is supported
   832  	Bus Address: 0000:00:01.3
   833  
   834  Handle 0x0043, DMI type 9, 17 bytes
   835  System Slot Information
   836  	Designation: PCIE3
   837  	Type: x16 PCI Express x16
   838  	Current Usage: In Use
   839  	Length: Short
   840  	ID: 2
   841  	Characteristics:
   842  		3.3 V is provided
   843  		Opening is shared
   844  		PME signal is supported
   845  	Bus Address: 0000:00:03.1
   846  
   847  Handle 0x0044, DMI type 9, 17 bytes
   848  System Slot Information
   849  	Designation: PCIE4
   850  	Type: x1 PCI Express x1
   851  	Current Usage: Available
   852  	Length: Short
   853  	ID: 3
   854  	Characteristics:
   855  		3.3 V is provided
   856  		Opening is shared
   857  		PME signal is supported
   858  	Bus Address: 0000:02:03.0
   859  
   860  Handle 0x0045, DMI type 9, 17 bytes
   861  System Slot Information
   862  	Designation: PCIE6
   863  	Type: x4 PCI Express x4
   864  	Current Usage: In Use
   865  	Length: Short
   866  	ID: 4
   867  	Characteristics:
   868  		3.3 V is provided
   869  		Opening is shared
   870  		PME signal is supported
   871  	Bus Address: 0000:02:04.0
   872  
   873  Handle 0x0046, DMI type 9, 17 bytes
   874  System Slot Information
   875  	Designation: J47
   876  	Type: x1 M.2 Socket 1-DP
   877  	Current Usage: In Use
   878  	Length: Short
   879  	Characteristics:
   880  		3.3 V is provided
   881  		Opening is shared
   882  		PME signal is supported
   883  	Bus Address: 0000:02:01.0
   884  
   885  Handle 0x0047, DMI type 9, 17 bytes
   886  System Slot Information
   887  	Designation: U3600
   888  	Type: x4 M.2 Socket 1-DP
   889  	Current Usage: Available
   890  	Length: Short
   891  	Characteristics:
   892  		3.3 V is provided
   893  		Opening is shared
   894  		PME signal is supported
   895  	Bus Address: 0000:40:01.1
   896  
   897  Handle 0x0048, DMI type 9, 17 bytes
   898  System Slot Information
   899  	Designation: U3601
   900  	Type: x4 M.2 Socket 1-DP
   901  	Current Usage: In Use
   902  	Length: Short
   903  	Characteristics:
   904  		3.3 V is provided
   905  		Opening is shared
   906  		PME signal is supported
   907  	Bus Address: 0000:40:01.2
   908  
   909  Handle 0x0049, DMI type 9, 17 bytes
   910  System Slot Information
   911  	Designation: PCIE5
   912  	Type: x8 PCI Express x8
   913  	Current Usage: Available
   914  	Length: Short
   915  	ID: 8
   916  	Characteristics:
   917  		3.3 V is provided
   918  		Opening is shared
   919  		PME signal is supported
   920  	Bus Address: 0000:40:01.3
   921  
   922  Handle 0x004A, DMI type 9, 17 bytes
   923  System Slot Information
   924  	Designation: PCIE7
   925  	Type: x16 PCI Express x16
   926  	Current Usage: Available
   927  	Length: Short
   928  	ID: 9
   929  	Characteristics:
   930  		3.3 V is provided
   931  		Opening is shared
   932  		PME signal is supported
   933  	Bus Address: 0000:40:03.1
   934  
   935  Handle 0x004B, DMI type 41, 11 bytes
   936  Onboard Device
   937  	Reference Designation: Onboard LAN Atheros
   938  	Type: Ethernet
   939  	Status: Enabled
   940  	Type Instance: 1
   941  	Bus Address: 0000:03:00.0
   942  
   943  Handle 0x004C, DMI type 41, 11 bytes
   944  Onboard Device
   945  	Reference Designation: Onboard LAN Realtek
   946  	Type: Ethernet
   947  	Status: Enabled
   948  	Type Instance: 2
   949  	Bus Address: 0000:05:00.0
   950  
   951  Handle 0x004D, DMI type 41, 11 bytes
   952  Onboard Device
   953  	Reference Designation: Audio Codec ALC1220
   954  	Type: Sound
   955  	Status: Enabled
   956  	Type Instance: 1
   957  	Bus Address: 0000:10:00.3
   958  
   959  Handle 0x004E, DMI type 41, 11 bytes
   960  Onboard Device
   961  	Reference Designation: Promontory SATA
   962  	Type: SATA Controller
   963  	Status: Enabled
   964  	Type Instance: 1
   965  	Bus Address: 0000:01:00.1
   966  
   967  Handle 0x004F, DMI type 41, 11 bytes
   968  Onboard Device
   969  	Reference Designation: DIE0 M.2 SATA
   970  	Type: SATA Controller
   971  	Status: Enabled
   972  	Type Instance: 2
   973  	Bus Address: 0000:10:00.2
   974  
   975  Handle 0x0050, DMI type 41, 11 bytes
   976  Onboard Device
   977  	Reference Designation: DIE2 M.2 SATA
   978  	Type: SATA Controller
   979  	Status: Enabled
   980  	Type Instance: 3
   981  	Bus Address: 0000:43:00.2
   982  
   983  Handle 0x0051, DMI type 127, 4 bytes
   984  End Of Table